Home / Shop


- Description
- Specifications
When both ports on a VWIC-2MFT-G703 are configured with the clock source set to line, they must use the same clock source, or timing slips can occur. The VWIC-2MFT-G703 is a Cisco 2-port E1 multiflex trunk interface card with G.703 support.
G.703 support lets the card pass unstructured E1 traffic, and a CSU/DSU is integrated on the card. The same clock source rule applies to the VWIC-2MFT-T1, VWIC-2MFT-E1 and VWIC-2MFT-E1-DI cards.
To comply with the Telcordia GR-1089 NEBS standard for electromagnetic compatibility and safety, the card connects only to intra-building or non-exposed wiring or cabling. The intrabuilding cable must be shielded, with the shield grounded at both ends.
The card is one of the VWICs supported in the NM-HDV2 network module. The 1-port card is the VWIC-1MFT-G703, and on the VWIC2-2MFT-G703 each port can be set to an independent clock source for data applications. More voice and WAN cards are in Cisco interface cards.
| Part number | VWIC-2MFT-G703 |
| Type | 2-port E1 multiflex trunk voice/WAN interface card with G.703 support |
| Ports | 2 |
| Traffic | Unstructured E1 conforming to ITU-T G.703 |
| CSU/DSU | Integrated |
| Clock source rule | Both ports set to line clock must use the same clock source |
| Wiring | Intra-building or non-exposed only; shielded cable, shield grounded at both ends |
| Supported in | NM-HDV2 network module with PVDM2 modules |
| Not supported in | ATM OC-3/STM-1 circuit emulation service network modules |
| One-port model | VWIC-1MFT-G703 |
| Second-generation model | VWIC2-2MFT-G703 |
| Compatible with | NM-HDV2 network module |