The X572001A is a NetApp NSM100 shelf module with a Non-Volatile Memory Express (NVMe) interface, supplied without a Power Supply Unit. NetApp's part description reads NSM100,NVMe,NoPSU, and the part is filed as a shelf module with a release date of May-2019.
NetApp's NS224 service guide covers NSM100 modules, where NSM means NVMe shelf module. An NSM can be swapped in an NS224 drive shelf that is powered on and handling input/output (I/O), as long as the partner NSM is up and cabled correctly. On an NSM100 the Dual Inline Memory Modules (DIMMs), fans and power supply move from the failed module to the new one, while the real-time clock battery is not moved, as the new module arrives with one preinstalled.
Leave at least 70 seconds between removing one NSM and installing the next, allowing ONTAP time to process the removal event. NSM firmware is checked every 10 minutes, and a firmware update on a module with non-current firmware can run up to 30 minutes. A shelf has three location LEDs, one on the operator display panel and one on each NSM, and they stay lit for 30 minutes once switched on.
More NetApp shelf modules and controller spares are gathered in the NetApp parts and accessories section of the Vertical Enterprise store.
| Part number | X572001A |
| Manufacturer | NetApp |
| Part type | Shelf module |
| Description | NSM100, NVMe, without Power Supply Unit |
| Module | NSM100 |
| Interface | Non-Volatile Memory Express (NVMe) |
| Power Supply Unit | not included |
| Release date | May-2019 |
| Compatible with | NS224 drive shelf (NSM100 module) |
| Moved from the failed module | DIMMs, fans, power supply |
| Real-time clock battery | preinstalled, not moved |
| Gap between removal and installation | at least 70 seconds |