- Description
- Specifications
IBM feature #EB3M is a 2000 W AC power supply for 200-240 V AC input, CCIN 51DE. It is used in the IBM Power System E950 (9040-MR9) and the IBM Power System E850C (8408-44E), and each of those servers runs with four of them. The part number is 00RY772 on the 9040-MR9 and 01EL710 on the 8408-44E.
On the Power E950 the four hot-plug supplies are always required. They are set up for N+1 redundancy with dual AC power cord tolerance, and a failed supply can be swapped while the server keeps running. Each supply takes a server line cord with a C19/C20 AC connector from the power distribution unit (PDU), together with the PDU-to-AC-source connector #4558, and the four supplies go to separate PDUs for electrical redundancy.
On the Power E850C the supplies are configured one-plus-one or two-plus-two for redundancy, in rack models only, and at least four must be present for the server to be operational. During a supply failure any of the four can be exchanged without interrupting the system. The E850C system unit has a maximum power consumption of 3,850 W and a maximum power source loading of 3.90 kVA at 200-240 V AC.
| Feature code | #EB3M |
| Description | AC Power Supply - 2000 W for Server (200-240 VAC) |
| CCIN | 51DE |
| Input | 200-240 V AC |
| Rated power | 2000 W |
| Machine types | 9040-MR9 (Power System E950), 8408-44E (Power System E850C) |
| Supplies per system | 4 |
| Part number, 8408-44E | 01EL710 |
| Part number, 9040-MR9 | 00RY772 |
| Redundancy, 9040-MR9 | N+1, dual AC power cord tolerance |
| Redundancy, 8408-44E | One-plus-one or two-plus-two; rack models only |
| Power cord connector, 9040-MR9 | C19/C20 to PDU (PDU to AC source connector #4558) |