Home » Store » IBM » IBM Misc » IBM #EB3M 2000 W AC Power Supply (200-240 VAC) for 9040-MR9 and 8408-44E

IBM #EB3M 2000 W AC Power Supply (200-240 VAC) for 9040-MR9 and 8408-44E

IBM #EB3M 2000 W AC power supply, CCIN 51DE, for the POWER9 Power System E950 (9040-MR9) and POWER8 Power System E850C (8408-44E).

Sourcing mission-critical hardware shouldn't mean gambling on auction sites or automated shopping carts. You get direct access to dedicated specialists who answer the phone, confirm exact compatibility, and deliver project-ready pricing built around your deployment timeline.

Home / Shop

IBM #EB3M 2000 W AC Power Supply (200-240 VAC) for 9040-MR9 and 8408-44E
IBM #EB3M 2000 W AC Power Supply (200-240 VAC) for 9040-MR9 and 8408-44E
IBM #EB3M 2000 W AC Power Supply (200-240 VAC) for 9040-MR9 and 8408-44E

Home / Shop

IBM #EB3M 2000 W AC Power Supply (200-240 VAC) for 9040-MR9 and 8408-44E

Model Number: IBM FC EB3M
IBM #EB3M 2000 W AC power supply, CCIN 51DE, for the POWER9 Power System E950 (9040-MR9) and POWER8 Power System E850C (8408-44E).
Maximum quantity exceeded
Minimum purchase amount of 0 is required
Maximum purchase amount of 0 is allowed
Missing Inquiry Options
*Your Name:
*Your Email:
*Your Message:
Please send me a copy
0.000
Categories: IBM Misc
Manufacturer: IBM
Facebook
X
Email
LinkedIn
  • Description
  • Specifications

IBM feature #EB3M is a 2000 W AC power supply for 200-240 V AC input, CCIN 51DE. It is used in the IBM Power System E950 (9040-MR9) and the IBM Power System E850C (8408-44E), and each of those servers runs with four of them. The part number is 00RY772 on the 9040-MR9 and 01EL710 on the 8408-44E.

On the Power E950 the four hot-plug supplies are always required. They are set up for N+1 redundancy with dual AC power cord tolerance, and a failed supply can be swapped while the server keeps running. Each supply takes a server line cord with a C19/C20 AC connector from the power distribution unit (PDU), together with the PDU-to-AC-source connector #4558, and the four supplies go to separate PDUs for electrical redundancy.

On the Power E850C the supplies are configured one-plus-one or two-plus-two for redundancy, in rack models only, and at least four must be present for the server to be operational. During a supply failure any of the four can be exchanged without interrupting the system. The E850C system unit has a maximum power consumption of 3,850 W and a maximum power source loading of 3.90 kVA at 200-240 V AC.

Feature code#EB3M
DescriptionAC Power Supply - 2000 W for Server (200-240 VAC)
CCIN51DE
Input200-240 V AC
Rated power2000 W
Machine types9040-MR9 (Power System E950), 8408-44E (Power System E850C)
Supplies per system4
Part number, 8408-44E01EL710
Part number, 9040-MR900RY772
Redundancy, 9040-MR9N+1, dual AC power cord tolerance
Redundancy, 8408-44EOne-plus-one or two-plus-two; rack models only
Power cord connector, 9040-MR9C19/C20 to PDU (PDU to AC source connector #4558)