NCS2006-AC is the AC power module for the Cisco NCS 2006 shelf, the 6RU, six-service-slot chassis of the NCS 2000 Series. The module has a single input that is universal in that it accepts 110 to 240 VAC at 50 to 60 Hz, and its output is -48.0 V DC. The spare number is NCS2006-AC=.
Output load is 1200 W from a 100 to 120 VAC (US nominal) 60 Hz supply and 1500 W from a 200 to 240 VAC (Europe nominal) 50 Hz supply. The NCS2006-AC supports the same specifications as the 15454-M6-AC2.
The shelf takes its AC feed on a standard 3-pole AC connector. Shelf power consumption depends on the configuration, at 130 W for the fan tray, LCD and ECU module. The fuse rating for an AC supply must not exceed 10 A, 15 A or 20 A depending on the country, and in North America the branch circuit protection must be rated 20 A.
In an AC-powered NCS 2006 the maximum power requirement is 1600 W, with 120 W for the fan-tray assemblies, and the AC power module itself accounts for 15 percent of the sum of the maximum consumption of all populated cards. NCS2006-AC is a supported supply for the NCS 2006 ECU-S alongside the DC modules NCS2006-DC, NCS2006-DC20 and NCS2006-DC40.
The shelf assembly measures 10.45 x 17.45 x 11.02 in (265.4 x 443.3 x 280 mm) and mounts in 19-, 21- or 23-inch racks or cabinets.
| Designation | AC power module, Cisco NCS 2006 |
| Shelf | Cisco NCS 2006 (6RU, 6 service slots) |
| Input | 110 to 240 VAC, 50 to 60 Hz, single input |
| Output voltage | -48.0 V DC |
| Load at 100-120 VAC (60 Hz) | 1200 W |
| Load at 200-240 VAC (50 Hz) | 1500 W |
| Equivalent | 15454-M6-AC2 specifications |
| AC connector | standard 3-pole |
| Shelf consumption | 130 W (fan tray, LCD, ECU) |
| Maximum fuse | 10 A, 15 A or 20 A by country |
| Spare number | NCS2006-AC= |