Home » Store » Cisco » Cisco Misc » NXA-PHV-1100W-PI Cisco Nexus 1100W Platinum HVAC/HVDC Power Supply, Port-Side Intake

NXA-PHV-1100W-PI Cisco Nexus 1100W Platinum HVAC/HVDC Power Supply, Port-Side Intake

Cisco Nexus N1100W Platinum HV-AC-DC power supply, port side intake. Part number NXA-PHV-1100W-PI.

Sourcing mission-critical hardware shouldn't mean gambling on auction sites or automated shopping carts. You get direct access to dedicated specialists who answer the phone, confirm exact compatibility, and deliver project-ready pricing built around your deployment timeline.

Home / Shop

NXA-PHV-1100W-PI Cisco Nexus 1100W Platinum HVAC/HVDC Power Supply, Port-Side Intake
NXA-PHV-1100W-PI Cisco Nexus 1100W Platinum HVAC/HVDC Power Supply, Port-Side Intake
NXA-PHV-1100W-PI Cisco Nexus 1100W Platinum HVAC/HVDC Power Supply, Port-Side Intake

Home / Shop

NXA-PHV-1100W-PI Cisco Nexus 1100W Platinum HVAC/HVDC Power Supply, Port-Side Intake

Model Number: NXA-PHV-1100W-PI
Cisco Nexus N1100W Platinum HV-AC-DC power supply, port side intake. Part number NXA-PHV-1100W-PI.
Maximum quantity exceeded
Minimum purchase amount of 0 is required
Maximum purchase amount of 0 is allowed
Missing Inquiry Options
*Your Name:
*Your Email:
*Your Message:
Please send me a copy
0.000
Categories: Cisco Misc
Manufacturer: Cisco
Facebook
X
Email
LinkedIn
  • Description
  • Specifications

Cisco's Nexus 9300-GX data sheet lists NXA-PHV-1100W-PI as the "N1100W Platinum HV-AC-DC PS, port side intake". It appears in the power supply options for the N9K-C9316D-GX, a 16-port 400/100G QSFP-DD spine switch, and the N9K-C93600CD-GX, which has 28 100/40G QSFP28 ports and 8 400/100G QSFP-DD ports.

The GX data sheet gives the high-voltage input range as 100 to 277 V AC and -240 to -380 V DC. Both of those switches take two 1100 W supplies in a 1+1 redundant pair. Cisco rates the 9316D-GX at 420 W typical and 1010 W maximum, and the 93600CD-GX at 586 W typical and 1071 W maximum.

The N9300-FX2 data sheet also lists NXA-PHV-1100W-PI among the power supplies for that series.

The matching port-side exhaust version is NXA-PHV-1100W-PE. The GX models pair these supplies with NXA-FAN-35CFM-PI or -PE fans.

Fit check: every supply and fan in one switch must share the same airflow, so use this intake unit only where the fans are also port-side intake.

This HVAC/HVDC supply is listed for spines such as the N9K-C9316D-GX; NXA-PAC-1100W-PI2 is the AC equivalent in Cisco Nexus spare parts.

NXA-PHV-1100W-PI Specs
Part numberNXA-PHV-1100W-PI
DescriptionN1100W Platinum HV-AC-DC PS
Rating1100 W
HVAC input100-277 V
HVDC input-240 to -380 V
Airflowport-side intake
Exhaust twinNXA-PHV-1100W-PE
Listed forN9K-C9316D-GX, N9K-C93600CD-GX, N9300-FX2 series
Redundancy1+1