Home » Store » Cisco » Cisco Misc » PWR-CH1-400WAC Cisco C8500L 400W AC Power Supply

PWR-CH1-400WAC Cisco C8500L 400W AC Power Supply

Cisco 400 W AC power supply module for the Catalyst 8500L-8S4X Edge Platform, with a spare form PWR-CH1-400WAC=.

Sourcing mission-critical hardware shouldn't mean gambling on auction sites or automated shopping carts. You get direct access to dedicated specialists who answer the phone, confirm exact compatibility, and deliver project-ready pricing built around your deployment timeline.

Home / Shop

PWR-CH1-400WAC Cisco C8500L 400W AC Power Supply
PWR-CH1-400WAC Cisco C8500L 400W AC Power Supply
PWR-CH1-400WAC Cisco C8500L 400W AC Power Supply

Home / Shop

PWR-CH1-400WAC Cisco C8500L 400W AC Power Supply

Model Number: PWR-CH1-400WAC
Cisco 400 W AC power supply module for the Catalyst 8500L-8S4X Edge Platform, with a spare form PWR-CH1-400WAC=.
Maximum quantity exceeded
Minimum purchase amount of 0 is required
Maximum purchase amount of 0 is allowed
Missing Inquiry Options
*Your Name:
*Your Email:
*Your Message:
Please send me a copy
0.000
Categories: Cisco Misc
Manufacturer: Cisco
Facebook
X
Email
LinkedIn
  • Description
  • Specifications

PWR-CH1-400WAC is the 400 W AC power supply for the Cisco Catalyst 8500L-8S4X Edge Platform (C8500L-8S4X), the Cisco C8500L 400W AC Power supply. PWR-CH1-400WAC= is the matching spare. The platform is always provided with a second, identical supply, so power continues if one supply fails or one input line is lost, and AC and DC supplies are never mixed in one chassis.

The AC module has a 424 W power rating and a 400 W output. Efficiency is 80 Plus Silver at 85% with 20% load, 89% at 50% load and 85% at 100% load. Input current is under 3 A at 200 Vac and under 6 A at 100 Vac, output holdup time is 20 ms (power-OK holdup 5 ms), and the input receptacle is an IEC 320 style inlet.

Each module has a retention latch, an AC socket, an Alarm Fail LED and a Status LED. The two supplies are hot-swappable, so with redundant supplies in use one can be replaced while the router stays in service. A blank must fill the slot until a new supply is installed. Connect each supply to a separate input power source, on its own circuit, so that one tripped breaker cannot take down the chassis.

The same chassis also takes the PWR-CH1-400WDC DC supply and the PWR-CC1-400WHV high-voltage AC/DC supply, which are the DC and HVAC/HVDC versions for the C8500L-8S4X.

DesignationPWR-CH1-400WAC
Spare formPWR-CH1-400WAC=
FitsCisco Catalyst 8500L-8S4X (C8500L-8S4X)
Input typeAC
Power rating424 W
Output400 W
Efficiency80 Plus Silver, 85% (20% load), 89% (50% load), 85% (100% load)
Input currentunder 3 A at 200 Vac, under 6 A at 100 Vac
Output holdup time20 ms
Input receptacleIEC 320 style
Redundancytwo identical supplies per chassis, hot-swappable